With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications.

[email protected]

News Detail

  • Chlorine Handling Manual - Hydro Instruments

    3 Information subject to change without notice. Doc. CL2-001 Rev. May 6, 2016 Chlorine Handling Manual WARNING Chlorine is a hazardous chemical that can cause injury and death if not handled properly. This manual contains only general information on the physical properties, storage, andFile Size: 899KB

    Get Price
  • C). A 100 PPD (2000 gr/hr) chlorinator was connected to

    Figure 1 illustrates the rate of chlorine discharge in pounds per day from a 150-pound (68 kg) cylinder, at 70 & F (21 & C). into the atmosphere (no back pressure) over a period of 20 hours. Curve A shows the rate of chlorine discharge over any given period of time when air is circulated by a

    Get Price
  • Chlorine Gas Safety Data Sheet SDS P4580

    Formula : Cl2 1.2. Relevant identified uses of the substance or mixture and uses advised against Use of the substance/mixture : Industrial use. Use as directed. 1.3. Details of the supplier of the safety data sheet Praxair, Inc. 10 Riverview Drive Danbury, CT 06810-6268 - USA T 1-800-772-9247 (1-800-PRAXAIR) - F 1-716-879-2146 www.praxair.com 1.4.File Size: 249KB

    Get Price
  • CHLORINE SAFETY SCRUBBING SYSTEMS

    3.4.1 Capacity/Rate for System Design 18 3.4.2 Capacity 18 3.4.3 Rate 19 3.4.4 Scrubbing Fluid 19 3.4.5 Heat Effects 20 3.5 Considerations for Scrubbing Effluents 21 3.5.1 Gas Discharge 21 3.5.2 Liquid Effluent 21 4 SYSTEM SAFETY CONSIDERATIONS 22 5 SYSTEM DESIGN 23 5.1 General 23 5.1.1 Principles 24 5.1.2 Design Documentation 25

    Get Price
  • How to calculate a gas leakage rate from a small hole of

    Lets go back to this question for a moment. We have a 4.4kg CL2 and 95.6 kg N2 contained within a cylinder at 103429 Torr (2000 psi). A leak occurs at one of the connection fittings, but for

    Get Price
  • How to Establish an Acceptable Leak Rate

    Application Bulletin: #120 Date: Oct 2014 . How to Establish an Acceptable Leak Rate Purpose: This Application Bulletin is to provide an overview of how to establish an acceptable leak rate. Purpose of Leak Testing Parts • Confirm manufacturing process is performing to specification and making good parts

    Get Price
  • Chlorine Safety: The Rest of the Story

    Jun 25, 2013For each lb. equivalent of Cl2: Salt (NaCl) 3.0 lbs Softened Water 15 gal Electrical energy 2 kWh For each pound of Cl2 equivalent produced: (15 gallons of 0.8% concentration Sodium Hypochlorite) 1/35 lb. of H2 gas produced (5.6 ft3) H2 gas Immediately diluted upon

    Get Price
  • Chlorine Standard Operating Procedure

    2. Put on appropriate personal protective equipment if a leak is known or suspected. 3. Turn on the light and visually ensure that the room is safe to enter (there may be visible signs of damage). 4. Close the main chlorine container valve. 5. Allow the system to purge itself of chlorine. Ensure that the float drops to the bottom of the feed-rate

    Get Price
  • How to handle chlorine gas safely

    there is an air leak in the system. Refer to instruction manual if an air leak is evident. 5. Loosen gas feeder yoke screw. Remove gas feeder from valve. 6. Replace gas cylinder. Be sure to use a chain or cable to secure the new cylinder properly. 7. Remove old lead gasket. Inspect and clean mating surfaces of gas feeder and valve. Install new

    Get Price
  • Material Safety Data Sheet Tetrafluoromethane CF4

    12-16% Breathing and pulse rate increased, muscular coordination slightly disturbed. 10-14% Emotional upset, abnormal fatigue, disturbed respiration. 6-10% Nausea and vomiting, collapse or loss of consciousness. Below 6% Convulsive movements, possible respiratory collapse and death. Tel: (732) 544-9899 Fax: (732) 544-9894 Toll Free: (800) 818-5109

    Get Price
  • CHEMICAL COMPATIBILITY CHART Metallic Materials Used in

    TR-60C (100-61-3) Rev. Ø; / 05-28-99 Page 2 of 28 Use or disclosure of data contained on this sheet is subject to the restrictions contained in the disclaimer located in the Table of Contents of this report

    Get Price
  • TR-052 Massive Leak of Liquefied Chlorine Gas

    A massive leak of liquefied chlorine gas created a dangerous cloud of poison gas over the city of Henderson, Nevada, in the early morning hours of May 6, 1991. Over 200 persons were examined . at a local hospital for respiratory distress caused by inhalation of the chlorine and approximately 30

    Get Price
  • SHERWOOD VALVE CHLORINE GAS PRODUCTS

    leak checking for quality, safety and reliability. We’re using the latest technology available to lower costs and increase quality. For example, Sherwood’s Industrial Automation Center produces up to 6500 assembled and tested valves per shift. And to help ensure quality for our customers, this equipment features automated self-diagnostic

    Get Price
  • THE CHLORINE MANUAL - Archer Instruments

    THE CHLORINE INSTITUTE, INC. MISSION STATEMENT The Chlorine Institute, Inc. exists to support the chlor-alkali industry and serve the public by fostering the continuous evaluation of and improvements to safety and the protection of human health and the

    Get Price
  • Chlorine | Cl2 - PubChem

    Chlorine is a commonly used household cleaner and disinfectant. Chlorine is a potent irritant to the eyes, the upper respiratory tract, and lungs. Chronic (long-term) exposure to chlorine gas in workers has resulted in respiratory effects, including eye and throat irritation and airflow obstruction. No information is available on the carcinogenic effects of chlorine in humans from inhalation

    Get Price
  • Sulfur Hexafluoride SF6 Safety Data Sheet SDS P4657

    Sulfur Hexafluoride Safety Data Sheet. according to U.S. Code of Federal Regulations 29 CFR 1910.1200, Hazard Communication. Date of issue: 01/01/1996

    Get Price
  • SAFETY DATA SHEET

    Chlorine Section 8. Exposure controls/personal protection chlorine ACGIH TLV (United States, 3/2016). STEL: 2.9 mg/m³ 15 minutes. STEL: 1 ppm 15 minutes.

    Get Price
  • Chlorine gas leak Detector M 4510 C - Controlmatik ABW

    The detection cell is mounted in an IP 65 housing and features 4- 20 mA output which is connected to the signal evaluation unit. Two adjustable alarms can be set and following units can be activated in case of chlorine gas leak:

    Get Price
  • Home - The Chlorine Institute

    What is the Chlorine Institute. The Chlorine Institute (CI) founded in 1924, is a technical trade association of companies involved in the safe production, distribution and use of chlorine, sodium and potassium hydroxides and sodium hypochlorite, the distribution and use of hydrogen chloride and the distribution of vinyl chloride monomer.

    Get Price
  • Chlorine (Cl2) - an overview | ScienceDirect Topics

    Ian Sutton, in Plant Design and Operations, 2015. Chlorine. Chlorine (Cl 2) is widely used to treat cooling water on process facilities.It is frequently stored under pressure as a liquid in 1-ton containers. (A leak from the liquid section of the container will be around 15

    Get Price
  • Helium Leak Detection in High Pressure Urea Reactor

    Heleum Leak Detection In High Pressure Urea Reactor Asia Nitrogen Syngas 2015 Conference (26 – 28 October 2015, Jakarta, Indonesia) 5 through the test part enters in the helium leak detector. The amount of the helium is directly proportional to the leak rate of the part.

    Get Price
  • Comparative study of Cl2,Cl2/O2, and Cl2/N2 inductively

    Comparative study of Cl 2,Cl 2/O 2, and Cl 2/N 2 inductively coupled plasma processes for etching of high-aspect-ratio photonic-crystal holes in InP C. F. Carlströma and R. van der Heijdenb COBRA Research Institute and Center for NanoMaterials, Eindhoven University of Technology,

    Get Price
  • Chlorine Safety

    9. If there is a leak, at least two persons should make the repairs. 10. Never spray water on leaking containers; it can make the leak worse. 11. When entering an equipment area, take shallow breaths until you are sure that there is not a chlorine gas leak. 12. Rely upon chlorination equipment for direct disposal of chlorine gas. 13.

    Get Price
  • Portable Chlorine (Cl2) Gas Detector, 0 to 10/50/100 ppm

    Portable Chlorine (Cl2) gas detector has measuring ranges of 0 to 10ppm / 20ppm / 50ppm / 100ppm for your selection, and give alarms with sound, light and vibration. Chlorine gas monitor uses high precision sensor, easy operation, high reliability and low price.

    Get Price
  • GENERAL GAS CHLORINE DESIGN - Force Flow

    Jan 25, 199916. Leak detectors shall be located 1 foot above the floor of the chlorine storage room and shall activate an alarm when a chlorine leak occurs. It is preferable that the detector be capable of differentiating between two or more chlorine concentrations

    Get Price
  • Standards and Design Guidelines for Wastewater Treatment

    Mar 09, 2018f. OM Manuals: Provide three (3) hard copies and three (3) CD/PDF searchable electronic copies of each OM manual. Hard copies shall be printed duplex 8.5”x11” in color on 24# bond paper with reinforced holes and bound in D-ring binders (maximum 4” binders per volume) with sheet lifters front and back, table of contents, and tabbed sections.

    Get Price
  • MultiRAE Lite Pumped | Honeywell

    With more than 25 sensors to choose from — the broadest selection in its class — it can test for VOCs, combustibles, and a range of toxic threats, as well as monitor sufficient oxygen levels, making it an excellent choice for personal protection and leak detection in a range of industries and applications.

    Get Price
  • SJRMC treated firefighters after chlorine leak | Northwest

    St. Joseph Regional Medical Center in Lewiston cared for two firefighters following a chlorine leak at Clearwater Paper earlier this month.The firefighters were employed by Medcor,…

edge-iconRelated News
toTop
Click avatar to contact us
Chat Online